Abstract

This work describes the development of an electrochemical sensor based on a molecularly imprinted polymer (MIP) for sensitive and selective determination of 4-ethylphenol in wine. The sensor has been built by means of the electrosynthesis of the MIP on a glassy carbon electrode surface using cyclic voltammetry. The electropolymerization has been performed in the presence of 4-ethylphenol and pyrrole as template molecule and functional monomer, respectively. The influence of the molar ratios of template molecules to functional pyrrole monomers and the time needed to remove the template have been optimized taking into account the differential pulse voltammetric response of 4-ethylphenol. Under the optimal experimental conditions the developed MIP/GCE sensor shows good capability of detection (0.2 μM, α = β = 0.05) and reproducibility (3.0%) in the concentration range from 0.2 to 34.8 μM. The influence of possible interfering species in the analytical response has been studied and the sensor has successfully been applied to the determination of 4-ethylphenol in different wine samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.