Abstract

Molecular weight (MW) of organics was one of the important factors influencing membrane fouling propensity. This study identified critical foulants of reverse osmosis (RO) membranes in reclaimed water by MW fractionation. MW > 10 kDa component was identified as the critical fouling contributor (CFC) in secondary effluent (SE), which accounted for only 13 ± 5% of dissolved organic carbon (DOC) but contributed to 86 ± 11% of flux decline. Throughout 12-month monitoring, SE and MW > 10 kDa component showed a similar fouling variation tendency: apparently higher fouling potential in winter and lower in summer, while MW < 10 kDa component presented minor fouling changes. Morphology of membrane fouled by CFC characterized a smooth and thick foulant layer on membrane surface. CFC was mainly composed of proteins and polysaccharides, and a protein-polysaccharide-protein “sandwich” fouling layer structure was preferentially formed on membrane surface. extended Derjaguin–Landau-Verwey–Overbeek (xDLVO) analysis demonstrated that strong attractive interactions between CFC and membrane surface dominated the fouling process. Furthermore, computational fluid dynamics (CFD) simulation revealed strong filtration resistance of CFC, confirming its significant fouling potential. Dual effects including attractive interactions and advantageous ridge-and-valley surface appearance accounted for the significant fouling propensity of MW > 10 kDa component and glean valuable insights into RO fouling mechanisms of reclaimed water in practical application.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call