Condensation of moisture on the epitaxial graphene on 6H-SiC was observed below room temperature despite continuous nitrogen flow on the graphene surface. Raman peaks associated with ice were observed. A combination of peaks in the frequency range of 500–750 cm−1, along with a broad peak centered at ~1327 cm−1, were also observed and were assigned to airborne contaminants. The latter is more important since its position is in the frequency range where the defect-associated D band of graphene appears. This band can be easily misunderstood to be the D band of graphene, particularly when the Raman spectrum is taken below room temperature. This peak was even observed after the sample was brought back to room temperature due to water stains. This work highlights the importance of careful Raman investigation of graphene below room temperature and its proper insulation against moisture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.