Abstract
The moire-based interferometry is demonstrated to significantly improve the measurement range in wafer-mask alignment by adopting two specifically designed four-quadrant grating marks. These relationships between the measurement range, the moire periods and the accuracy of the moire-based detection algorithm are deduced. By demodulating the transverse shifts of the moire fringes with two kinds of periods, the final misalignment can be accurately determined. An experimental setup of the wafer-mask alignment is constructed to explore the feasibility and effectiveness of proposed approach. Results indicate that with the established configurations, the measurement range can be readily extended to 120 mu m, which is dozens of times larger than conventional methods, and meanwhile the detection accuracy retains to be at nanometers level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.