: We present a modified floating wire technique for aorto-ostial coronary stenting. This novel approach ensures accurate ostial alignment without stent protrusion. The technique involves using a second wire as a marker at the true ostium to guide optimal stent placement. A balloon catheter is advanced on the floating wire to delineate the aorto-ostial plane. This method reduces the need for contrast media, prevents deep intubation of the guide catheter, and resembles the stent draw-back technique. The modified floating wire technique offers a safe and effective method for aorto-ostial coronary stenting and has potential for broader clinical application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.