Abstract

This paper presents an improved dc-link voltage balancing algorithm for a three-level neutral-point-clamped inverter by considering phase current direction. Detailed studies on the effects of change in load current direction on the dc-link capacitor voltages are presented. A maximum value of power factor is numerically derived, above which it affects the capacitor voltage balancing capability. Compared with the previously presented research work, the inputs to the space-vector pulsewidth-modulation block are the three phase currents and the difference between the two capacitor voltages. Depending on the states of the two dc-link capacitor voltages and phase current direction, redundant voltage vector sequences are selected. The selected vectors keep the capacitor voltage deviations within 5% of the total dc-link voltage. Two zero switching vectors (i.e., PPP and NNN) are also removed from all subsectors of the earlier proposed strategy, which one used to produce higher common-mode voltages. Detailed simulation and experimental results are presented in this paper for a 6.0-kW surface permanent-magnet synchronous machine. Both the simulation and experimental results show the required performance of the proposed system.