Abstract

A requirement of the three-level neutral-point-clamped voltage source inverter, with or without a separately supporting dc link, is to maintain the balance of the two dc-link capacitor voltages. In this paper, balancing of the capacitor voltages for these two dc-link voltage source possibilities is analyzed and an algorithm is proposed to independently balance the capacitor voltages. The algorithm considers the average energy effect of each vector on capacitor voltage and the necessary optimal vector state sequence in each modulation cycle. The algorithm minimizes the voltage rating overheads of the hardware, reduces the voltage ripple, and attenuates the negative effects associated with dc-link voltage oscillations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.