Dried blood spots (DBSs) provide an alternative sample input for serologic testing. We evaluated DBSs for the ARCHITECT® hepatitis B surface antigen (HBsAg) NEXT, hepatitis B e-antigen (HBeAg), anti-hepatitis B core antigen (anti-HBc II), HIV antigen/antibody (Ag/Ab) Combo and AdviseDx SARS-CoV-2 IgG II assays. Assay performance with DBSs was assessed with or without assay modification and compared with on-market assay with plasma samples. DBS stability was also determined. HBsAg NEXT and HIV Ag/Ab Combo assays using DBSs showed sensitivity and specificity comparable to that of on-market assays. Modified HBeAg, anti-HBc II and SARS-CoV-2 IgG II DBS assays achieved performance comparable to on-market assays. Use of DBSs as input for high-throughput serologic assays is expected to have significant implications for improving population surveillance and increasing access to diagnostic testing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.