Abstract

The maximum controllable on-state current, I/sub M/, of a multi-island GTO, is calculated as a function of the number of islands. The limit considered is based upon the premise that if the instantaneous current through the cathode of an island exceeds a critical value i/sub c/, then that island, and hence the GTO, will not turn off. Our approach is based upon the observed variation in the storage times of individual islands after the initiation of the gate turn-off current. The distribution of storage times is treated as a distribution of random numbers. Both a homogeneous and a Gaussian distribution are treated. The functional form in time of the fall in current through an island, after the storage time was also found to be important. If an island shuts off within a time short compared to the spread in storage times, then I/sub M/ will be small and not scale with the number of islands N. The conditions under which I/sub M//spl sim/N might be obtained are discussed.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call