Abstract

In this paper, novel small-signal averaged models for dc–dc converter operating at variable switching frequency are derived. This is achieved by separately considering the on-time and the off-time of the switching period. The derivation is shown in detail for a synchronous buck converter. The Enhanced Small Signal (ESSA) Model is derived for the synchronous buck converter. The equivalent series inductance (ESL) is also considered in this modelling. The buck converter model is also simulated in MATLAB and the result is also presented. DOI: http://dx.doi.org/10.11591/ijpeds.v5i2.6472

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.