Thermomechanical microactuators possess a number of desirable attributes including ease of fabrication and large force and displacement capabilities relative to other types of microactuators. These advantages provide motivation for improving thermomechanical microactuator designs that are more energy efficient and thus better suited for low-power applications. To this end, this paper describes the development and experimental validation of a finite-difference thermal model of a thermomechanical in-plane microactuator (TIM). Comparisons between the model and experimental results demonstrate the importance of including the temperature dependence of several parameters in the model. Strategies for reducing the power and energy requirements of the TIM were investigated using model simulations as a guide. Based on design insights gained from the model, the energy efficiency of the TIM has been improved significantly by operating in a vacuum environment and providing short-duration, high-current pulse inputs. These improvements have been validated experimentally.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.