Abstract

Per- and polyfluoroalkyl substances (PFAS) are increasingly of interest to drinking water utilities due to state regulations, the release of federal and state health advisories, and public concern. Pilot-scale data were fitted for 16 PFAS species and five commercial-activated carbons using an open-source pore and surface diffusion model that includes an automated parameter-fitting tool. The estimated model parameters are presented, and an uncertainty analysis was evaluated considering the expected temporal variability of influent concentrations. Expected treatment performance differed between two seasons in the pilot phase for the same carbon, which was not captured by modeled uncertainty. However, modeling results can support a utility's decision to choose activated carbon, and make design and operational decisions that can address changing water production rates and treatment goals. For the utility that undertook this pilot study and their desired treatment goals, granular activated carbon (GAC) was found to be an effective treatment technology for PFAS removal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.