Abstract

The paper considers the reverberation chamber (RC) method for the measurement of the shielding effectiveness (SE) of coaxial cables with braided shields. In particular, the voltage at the cable termination is numerically computed and compared to that measured in an RC. The RC field is represented by a finite summation of random plane waves, and a finite-difference time-domain (FDTD) code is used to calculate the outer shield current induced by the RC field. The knowledge of the shield current distribution allows the determination of the voltage at the cable termination's internal circuit after a proper numerical averaging. It is then compared to the measured voltage averaged over stirrer rotations. The method is applied to a commercially available cable model RG58, and using the nominal value for the transfer impedance of this cable type gives results in a satisfactory agreement with the measurements. Finally, the possibility of recovering the transfer impedance from the measured SE of the RC is discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.