The reverberation chamber (RC) method has many advantages above the semi anechoic room (SAR) method. The RC method is specifically useful to measure emissions at high frequencies (>1 GHz). This is an important property when we consider the trend of increasing operating frequencies of products and wireless applications. Furthermore, the RC method is useful for immunity tests, where we only need moderate power for generating suitable test levels. However, when different methods are used, the topic of conversion arises. In this paper, we specifically consider practical evaluation of the conversion factor of emission results of a CISPR 22 system-test EUT configuration. In addition, we investigate the practical conversion factor of an artificial EUT. From these evaluations, it could be concluded that the RC method is suitable for performing compliance emission measurements and that a conversion factor of around 4 dB is applicable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.