Abstract
In this paper a simple dynamic model for induction machines (IM) with inter-turn winding fault is established. Finite element method is used for parameter identification of the machine under fault condition. The proposed dynamic model is validated by time stepping finite element (FE) analysis. The dynamic model results exhibit the same trend as predicted by FE analysis for different fault insulation resistances. This model is well adapted for IM health monitoring and inter-turn fault diagnosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have