Abstract
This paper attempts to analyse the characteristics of the inter-turn short circuit fault for the permanent magnet synchronous motor (PMSM). Based on finite element analysis (FEA), the influence of the stator faults on the behaviour of the PM machine is studied. A simple dynamic model for a PM machine with inter-turn winding fault is presented. The precision of the proposed finite element (FE) model is verified by a comparison of the simulation results tests. Using the simulated model, a technical method, based on fast fourier transform (FFT) analysis of stator current and electromagnetic torque, is exported to detect the inter turn fault. The technique used and the obtained results show clearly the possibility of extracting signatures to detect and locate faults.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Digital Signals and Smart Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.