Abstract

An improved brushless AC motor model is proposed for use in signal-injection-based sensorless control schemes by accounting for cross-coupling magnetic saturation between the d- and q-axes. The incremental self- and mutual-inductance characteristics are obtained by both finite-element analysis and measurements, and have been successfully used to significantly reduce the error in the rotor position estimation of sensorless control

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.