Abstract
A main requirement for the implementation of model-based process development in industry is the capability of the model to predict high protein load densities. The frequently used steric mass action isotherm assumes a thermodynamically ideal system and, hence constant activity coefficients. In this manuscript, an industrial antibody purification problem under high load conditions is considered where this assumption does not hold. The high protein load densities, as commonly applied in industrial downstream processing, may lead to complex elution peak shapes. Using Mollerup's generalized ion-exchange isotherm (GIEX), the observed elution peak shapes could be modeled. To this end, the GIEX isotherm introduced two additional parameters to approximate the asymmetric activity coefficient. The effects of these two parameters on the curvature of the adsorption isotherm and the resulting chromatogram are investigated. It could be shown that they can be determined by inverse peak fitting and conform with the mechanistic demands of model-based process development.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have