The sizing of a solar thermal system to feed the water distillers in the laboratory of the Santander Technological Units is presented, proposing a comparative study between three calculation methods (f-chart, instantaneous and ACSOL) for the estimation of the surface of solar capture, finally supported by modeling in the TRNSYS software of the final system, to evaluate its behavior dynamically during one year. Initially, a search for information is carried out to establish the models to develop each of the calculation methods, additionally technical data is collected from the laboratory equipment to determine the consumption of hot water. Subsequently, each of the calculation methods is applied in order to size the catchment surface, to finally carry out a comparative study between the results obtained, determining which is the most appropriate method for the calculation and defining the dimensions of the same, to develop a modeling of the dynamic behavior of the system through the TRNSYS Software. The final result presents a storage system with an average temperature of 62.13 ° C and solar collectors with an average temperature of 58.7 ° C for one year of operation. Finally, the operating time of the resistive stills is reduced from 11 hours a day to 6 hours with the integration of the Thermosolar system.