Abstract

The influence of ambient temperature and moisture content on the performance of Transcorp Power Plant, Ughelli, Delta State, Nigeria was investigated with the aid of a digital psychrometer. The simulation was done using codes developed on MATLAB R2017a and the results show that compressor power consumption increased by 1.65% for 0.7% rise in temperature, and 0.50% for 71.4% rise in moisture content. The specific fuel consumption also increased with increase in temperature where a 1.71% rise in ambient temperature resulted in a 0.15% rise in specific fuel consumption but it decreased by 0.49% for a 41.7% rise in moisture content. A 1.62% rise in temperature led to a 0.13% drop in net power output and a 29.4% rise in moisture content resulted in a 0.48% drop in net power output. Thus gas turbine plant operates optimally in areas with low ambient temperatures and high moisture content.
 Keywords: Work ratio, net power, efficiency, moisture content, specific fuel consumption, heat rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.