Abstract

As an essential transportation equipment for personnel to access offshore wind plants, the safety and stability of the turbine access system (TAS) have gained increasing significance. However, when sea conditions deteriorate, the end of the TAS will experience large-angle shaking and an increase in the heave height. A novel 3-DOFs TAS with active motion compensation for the Fujian coastal area is designed to solve the problem of the stability of the end of the TAS under sea conditions with a significant wave height of 2.2 m, including structural design, kinematic analysis, hydraulic drive design, and control system design. In the research, a new stacking compensation method is proposed to compensate for the roll angle, pitch angle, and heave height at the end of the TAS. The 3-DOFs TAS is modeled mathematically by the Denavit–Hartenberg parameters, and the hydraulic system model is established. In order to improve the compensation effect, a fuzzy PID controller with feedforward compensation is designed based on fuzzy PID control, and the model simulation experiment is carried out by MATLAB/Simulink. Finally, the experimental simulation shows that under the compensation of the feedforward compensation fuzzy PID control algorithm and the new compensation algorithm, the roll angle of the TAS is reduced by a maximum of 84.8%, the pitch angle is reduced by 75%, and the heave height is reduced by 73.6%. This validates the effectiveness of the proposed scheme and provides a reference for future TAS design and development.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call