Abstract

The single-phase isolated quasi-single-stage AC-DC converter has many virtues, such as high power density and efficiency; however, its grid current closed-loop control has not been solved. This paper aims to solve the remaining gap based on a large-signal model. In this paper, the large-signal model of this converter under triple-phase-shift modulation is built for the first time. It is verified that the built model is a zero-order linear system. Based on this built model, the effect of grid harmonics on this converter grid current is analyzed. The theoretical analysis reveals that the grid voltage low-order harmonics will cause the same order grid current harmonics and only varying the parameters of the filter is not an effective method to solve this problem. For the purpose of eliminating the effect of grid voltage harmonics on the grid current and realizing the zero-error control of the fundamental component of the grid current, a grid current closed-loop control strategy based on the proportional-resonant compound odd-mode repetitive controller is proposed. The operation principle, parameter constraint, and design rule of the proposed compound control strategy are analyzed comprehensively. The theoretical analysis and the compound control strategy put forward in this paper are tested, with detailed experimental results.