Abstract

This paper proposes a robust control scheme for the grid-connected single-phase converter of small permanent-magnet synchronous generator (PMSG) wind turbines under distorted grid voltages. The single-phase grid current is controlled to be sinusoidal by eliminating the high-order harmonic components. For this, the fundamental and high-order harmonic components of the grid voltage and current are extracted by the composite observer without a delay. Then, a phase-lock loop (PLL) scheme is employed for the fundamental component of the grid voltage to detect the phase angle of the grid voltage for the grid current controller. The multi-PR (proportional-resonant) controllers are used to regulate the grid current. In the system, the boost converter controls the DC-link voltage and the grid converter controls the generator output power. The validity of the proposed scheme is verified by the simulation and experimental results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.