Abstract

Abstract In this research, the integrated carbon dioxide power cycle with a geothermal energy source to supply the required reverse osmosis desalination power for freshwater production is defined. It is also a carbon dioxide power cycle, coupled with thermal energy recovery of infrared energy of liquid natural gas (LNG) to generate more power. A sodium hypochlorite generator is considered to prevent the brine water discharging. The brine water portion of the desalination outlet was the input to this generator. The cycling power is consumed by the desalination system and sodium hypochlorite generator. After modeling, the advanced exergy analyses are studied. By exergy analysis, it is observed that in this model the condenser has the highest exergy destruction rate, equal to 952 kW. Additionally, the unavoidable part of the exergy destruction of carbon dioxide turbine constitutes 88% of its exergy destruction that is equal to 301 kW. So this component is the best option to improve exergy destruction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.