Abstract

Mineral scaling in water desalination is caused by the precipitation of salts, which is affected by various factors such as the presence of specific ions, solution pH, and temperature. While extensively researched in technologies like reverse osmosis (RO), understanding mineral scaling in membrane capacitive deionization (MCDI) remains limited. During MCDI operation, the pH of the effluent fluctuates, potentially triggering mineral scaling. The present study investigates how the adsorption and desorption of HCO3− ions and the distribution of dissolved inorganic carbon (DIC) species (H2CO3, HCO3−, and CO32−) drive pH changes. We examine mineral scaling formation at various water recoveries during MCDI operation using different thicknesses of the anion exchange membrane (AEM). Our findings indicate that pH changes increase with higher water recoveries and that increasing the AEM thickness provides a pathway to enhance MCDI stability, consequently lowering the need for anti-scaling agents.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.