Abstract

Analysis has been performed for an anticipated transient without scram (ATWS) event in a simplified boiling water reactor. Loss of feedwater heating initiated this ATWS, which was mitigated by the insertion of fine-motion control rods. Calculations with RAMONA-4B code show that reactivity insertion, through increase in subcooling to the core, results in a rise in the core power to a new equilibrium condition. Insertion of fine-motion control rods from the bottom of the core is found to shift the peak of the axial power distribution to the upper part of the core until eventual shutdown of the reactor occurs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.