Abstract
Particle contamination due to plasma processing motivates the design of a method of electrically lifting particles in a time interval after a plasma’s power is turned off. Small solid dust particles have electric charges that are not frozen until a late stage of the plasma afterglow. Beyond that time, before they fall to a surface below and cause defects, particles can be lifted in a controlled manner by applying an appropriate direct-current (DC) electric field, as we demonstrate experimentally. A few milliseconds after an argon plasma’s capacitively coupled radio-frequency power is switched off, a vertical DC electric field is applied. Thereafter, video imaging shows that the falling of the particles is slowed or stopped altogether, depending on the magnitude of the upward electric force.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.