Abstract

The nonuniform and high-gradient solar radiation flux on the absorber surface of solar dish concentrator/cavity receiver (SDCR) system will affect its operational reliability and service lifetime. Therefore, homogenization of the flux distribution is critical and important. In this paper, 2 mirror rearrangement strategies and its optimization method by combining a novel ray tracing method and the genetic algorithm are proposed to optimize the parabolic dish concentrator (PDC) so as to realize the uniform flux distribution on the absorber surface inside the cavity receiver of SDCR system. The mirror rearrangement strategy includes a mirror rotation strategy and mirror translation strategy, which rotate and translate (along the focal axis) each mirror unit of the PDC to achieve multipoint aiming, respectively. Firstly, a correlation model between the focus spot radius and mirror rearrangement parameters is derived as constraint model to optimize the PDC. Secondly, a novel method named motion accumulation ray-tracing method is proposed to reduce the optical simulation time. The optical model by motion accumulation ray-tracing method and optimization model of SDCR system are established in detailed, and then, an optimization program by combining a ray-tracing code and genetic algorithm code in C++ is developed and verified. Finally, 3 typical cavity receivers, namely, cylindrical, conical, and spherical, are taken as examples to fully verify the effectiveness of these proposed methods. The results show that the optimized PDC by mirror rearrangement strategies can not only greatly improve the flux uniformity (ie, reduce the nonuniformity factor) and reduce the peak local concentration ratio of the absorber surface but also obtain excellent optical efficiency and direct useful energy ratio. A better optimization results when the PDC is optimized by mirror rotation strategy at aperture radius of 7.0 m, focal length of 6.00 m, and ring number of 6; the nonuniform factor of the cylindrical, conical, and spherical cavity receivers is greatly reduced from 0.63, 0.67, and 0.45 to 0.18, 0.17, and 0.26, respectively; the peak local concentration ratio is reduced from 1140.00, 1399.00, and 633.30 to 709.10, 794.00, and 505.90, respectively; and the optical efficiency of SDCR system is as high as 92.01%, 92.13%, and 92.71%, respectively. These results also show that the dish concentrator with same focal length can match different cavity receivers by mirror rearrangement and it can obtain excellent flux uniformity.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call