Abstract

Using a modular dual-mobility (MDM) bearing in primary total hip arthroplasty (THA) has not been widely evaluated. The purpose of this study is to evaluate clinical outcomes and survivorship following MDM bearings in primary THA. We used our registry database for patients with an MDM bearing on primary THA, performed by 6 surgeons through supine direct lateral or direct anterior approach. MDM bearings were used most often when impingement or subluxation was present intraoperatively despite proper component position. Another indication was a patient with planned activities who might be at a higher risk of instability postoperatively. A total of 127 MDM bearings were used in primary THA in 119 patients. Mean follow-up was 6.77 years (range 5-8.9). Five hips were revised, none of which were due to MDM bearing failure. Preoperative Hip dysfunction and Osteoarthritis Outcome Score for Joint Replacement, Veterans RAND/Short Form 12 Physical Health Score and Mental Health Score increased from 25.81 to 52.40 (P < .0001), 30.42 to 44.50 (P < .0001), and 36.21 to 52.70 (P < .0001) at latest completed survey follow-up, respectively. This MDM bearing shows excellent functional outcomes at a minimum 5 years of follow-up with no bearing-related failures. It can be an excellent choice in primary THA specifically in females where the use of increased head size to prevent instability is not possible due to anatomical restrictions and liner thickness.