Abstract
The purpose of this investigation is to propose a strategy for minimizing the creation of spent pickling liquors through the synergistic corrosion inhibition of OP-10 and potassium iodide, thus facilitating a cleaner production process for acid pickling of metals with a high-concentration solution (6.0 mol/l) of hydrochloric acid. Results obtained with the methods of weight loss and electrochemical polarization showed that adding KI and OP-10 could enhance the energy barrier of the corrosion reaction and improved the corrosion inhibition for mild steel in high concentration of HCl solutions. A synergistic effect was identified when KI and OP-10 were present in suitable proportions. The results of the electrochemical experiments and scanning electron microscope (SEM) observations showed that the complex inhibitor was a mixed-type inhibitor and it formed a compact film on the metal surface, thus providing an effective protection for the metal in the aggressive solutions, which significantly minimized the creation of spent pickling liquors. A simple and convenient method was also proposed for the quantificational evaluation of the inhibition degree in the creation of spent pickling liquors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.