Abstract

BackgroundPelvic ring injuries constitute only 2 to 8% of all fractures; however, they occur in 20% of polytrauma patients. High-energy pelvic fractures often result in mechanical instability of the pelvic ring. Successful treatment of unstable pelvic ring fractures remains a challenge for orthopedic surgeons. This study presents a novel internal fixation method for stabilizing unstable anterior pelvic ring fractures using a minimally invasive modified pedicle screw-rod fixation (MPSRF) technique.MethodsThis retrospective study included six patients with unstable pelvic ring injuries who underwent MPSRF, with or without posterior fixation. Intraoperative parameters such as blood loss, operative time, complications, and quality of reduction (Matta criteria) were recorded and evaluated by a blinded reviewer.ResultsIn the present clinical series, the mean operative times and mean blood loss for unilateral versus bilateral anterior ring fixations were 176.0 min versus 295.6 min, and 153.3 mL versus 550.0 mL, respectively. No iatrogenic neuropraxia of the lateral femoral cutaneous nerve or femoral nerve palsy occurred. The reduction quality, graded by the Matta criteria, was excellent in five patients and good in one patient.ConclusionsThere were no infections, delayed unions, nonunions, or loss of reductions during the follow-up period. Only one patient suffered from a broken rod at 4 months postoperatively. The modified technique represents a novel, minimally invasive procedure for the treatment of anterior pelvic ring fractures and offers a reliable and effective alternative to currently available surgical techniques.

Highlights

  • Pelvic ring injuries constitute only 2 to 8% of all fractures; they occur in 20% of polytrauma patients

  • We aimed to evaluate the clinical application of this minimally invasive modified pedicle screw-rod fixation (MPSRF) technique for the treatment of anterior pelvic ring fractures

  • To combine the advantages of the pedicle screw-rod system and the pelvic bridge techniques for treating unstable anterior pelvic ring fractures, we designed a new form of minimally invasive pelvic fixation using pedicle screw-rod fixators, which were applied submuscularly from the iliac wing to the superior pubic ramus

Read more

Summary

Introduction

Pelvic ring injuries constitute only 2 to 8% of all fractures; they occur in 20% of polytrauma patients. Successful treatment of unstable pelvic ring fractures remains a challenge for orthopedic surgeons. This study presents a novel internal fixation method for stabilizing unstable anterior pelvic ring fractures using a minimally invasive modified pedicle screw-rod fixation (MPSRF) technique. Pelvic ring injuries constitute only 2 to 8% of all fractures but occur in 20% of polytrauma patients [1]. Stabilization of anterior pelvic ring fractures can be achieved via multiple techniques, including external fixation [3], open reduction and internal fixation with plating, or percutaneous trans ramus screw fixation [4]. Open reduction has the potential disadvantage of an extensive exposure, Hung et al Journal of Orthopaedic Surgery and Research (2018) 13:238 which includes muscle stripping, and the risk of damage to neurovascular structures [7]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call