Abstract

Central MessageRobotic technology facilitates sophisticated mitral valve repair via small incisions with the quickest recovery and in a manner that is most acceptable to the patient.See Commentaries on pages 80 and 82. Robotic technology facilitates sophisticated mitral valve repair via small incisions with the quickest recovery and in a manner that is most acceptable to the patient. See Commentaries on pages 80 and 82. Asking the question “What is the best minimally invasive mitral valve operation?” is fraught with the same problems as asking, “What is the best … city, …car, …football team?” etc. It depends not only on what factors one considers important but also on how one weights each of those. While there are some parameters in mitral valve (MV) surgery that most would agree are fundamental and commonly measured, such as mortality and rate of repair, there are others that are more nebulous. Many factors important to patients, such as recovery time, return to normal activity, cosmesis, avoidance of long-term medication, and reintervention, are frequently not considered and are difficult to measure. The situation is further complicated by the need to accommodate not one viewpoint but multiple perspectives, such as the patient, the surgeon, and the health care system. In many circumstances, these needs are antithetical. For many reasons, the evidence to support superiority of one surgical approach over another is profoundly limited. We are not comparing one pill with another; rather, we are comparing complex management systems with individual clinicians at the core. Because of this, surgery does not lend itself to randomized controlled studies. The biases of patient selection, pathologic complexity, and outcome definition (and many others) make comparison between case series virtually impossible. However, at the most basic level, irrespective of approach, the “best” MV surgery needs to prove its efficacy and safety. So how does robotic mitral surgery measure up compared with the standard approach through median sternotomy? Over the last 20 years, several North American centers have achieved high-volume robotic mitral experience with good outcomes. In 2015, Murphy and colleagues1Murphy D.A. Moss E. Binongo J. Miller J.S. Macheers S.K. Sarin E.L. et al.The expanding role of endoscopic robotics in mitral valve surgery: 1,257 consecutive procedures.Ann Thorac Surg. 2015; 100 (discussion 81-2): 1675-1681Abstract Full Text Full Text PDF PubMed Scopus (81) Google Scholar reported outcomes in 1257 consecutive cases of robotic MV surgery, of which 93% were MV repair. Mortality was 0.9% and stroke in 0.7%. Predischarge echocardiogram showed trace or mild mitral regurgitation (MR) in more than 98% of repaired valves and at a mean follow-up of 50 ± 26 months, 3.8% patients required reoperation. Gillinov and colleagues2Gillinov A.M. Mihaljevic T. Javadikasgari H. Suri R.M. Mick S.L. Navia J.L. et al.Early results of robotically assisted mitral valve surgery: analysis of the first 1000 cases.J Thorac Cardiovasc Surg. 2018; 155: 82-91.e2Abstract Full Text Full Text PDF PubMed Scopus (77) Google Scholar reported similar outcomes in their first 1000 robotic mitral procedures, with an in-hospital mortality of 0.1% and stroke rate of 1.4%, which declined from 2% in the first 500 patients in the series to 0.8% in the second 500 patients. More than 99% were planned MV repair, and 97.8% of these had mild or less MR on the predischarge echocardiogram. These results are comparable with results achieved through sternotomy, such as reported by Castillo and colleagues,3Castillo J.G. Anyanwu A.C. Fuster V. Adams D.H. A near 100% repair rate for mitral valve prolapse is achievable in a reference center: implications for future guidelines.J Thorac Cardiovasc Surg. 2012; 144: 308-312Abstract Full Text Full Text PDF PubMed Scopus (191) Google Scholar where more than 99% were valve repairs, with 0.8% mortality and 0.5% major stroke rate. Although there are no randomized trial data (the likelihood of there ever being such a trial is low), a meta-analysis of robotic versus sternotomy approaches showed similar overall outcomes.4Cao C. Wolfenden H. Liou K. Pathan F. Gupta S. Nienaber T.A. et al.A meta-analysis of robotic vs. conventional mitral valve surgery.Ann Cardiothorac Surg. 2015; 4: 305-314PubMed Google Scholar These results demonstrate what is possible with robotic approach when it comes to efficacy and safety. Although as surgeons we have all strived to achieve the best long-term outcome for our patients, we must also consider achieving this with the quickest recovery and in a manner that is most acceptable to the patient. It is clearly the aim of minimally invasive approaches to address these needs, robotic or otherwise. While there is, perhaps, a gradation in minimally approaches from partial sternotomy,5Nair R.U. Sharpe D.A. Limited lower sternotomy for minimally invasive mitral valve replacement.Ann Thorac Surg. 1998; 65: 273-274Abstract Full Text Full Text PDF PubMed Scopus (24) Google Scholar right thoracotomy with direct or thoracoscopic vision6Glauber M. Miceli A. Canarutto D. Lio A. Murzi M. Gilmanov D. et al.Early and long-term outcomes of minimally invasive mitral valve surgery through right minithoracotomy: a 10-year experience in 1604 patients.J Cardiothorac Surg. 2015; 10: 181Crossref PubMed Scopus (62) Google Scholar to robotic, with each of these there are advantages and disadvantages. Partial sternotomy MV repair is in many ways a hybrid minimally invasive approach. It is surgically more familiar than other approaches and therefore will have a shorter learning curve. However, it does come with limitations: in many, the incision is difficult to hide, and access to the MV suffers from the same limitation as through a full sternotomy. The right thoracotomy direct vision approach with or without endoscopic assistance is probably the most widely adopted minimally invasive approach. Cosmesis is superior, especially in women (in whom the incision can be hidden in the breast crease). Thoracoscopic techniques enable a small cosmetic incision and an excellent view of the valve. Although it requires the use of peripheral cannulation and shafted instruments, the skill sets required are easily adaptable from open mitral surgery, and this has been adopted as standard of care in many large-volume centers. Indeed, a recent meta-analysis have shown similar efficacy and safety using a minimally invasive approach as compared with standard sternotomy approach.7Sa M. Van den Eynde J. Cavalcanti L.R.P. Kadyraliev B. Enginoev S. Zhigalov K. et al.Mitral valve repair with minimally invasive approaches vs sternotomy: a meta-analysis of early and late results in randomized and matched observational studies.J Card Surg. 2020; 35: 2307-2323Crossref PubMed Scopus (6) Google Scholar However, due to the intrinsic limitation of the instruments, we feel this thoracoscopic approach may narrow the repertoire of mitral repair techniques used. Shafted instruments have limited freedom of movement at the tissue interface. A static left atrial (LA) retractor lacks versatility in visualizing the various components of the mitral apparatus. In addition, fundamentally, with endoscopic MV surgery, the operation is largely carried out by a single operator via shafted instruments with very little room for active assisting from a second operator. In the authors' opinion, the robotic platform overcomes the limitations of the thoracoscopic approaches. The high-resolution 3-dimensional camera combined with the flexibility of a dynamic LA retractor affords an unsurpassed view of the valve and its components. It is simple to gain access to the subvalvular apparatus for neochord placement. The retractor may also be adjusted to aid closure of the LA appendage or a patent foramen ovale and to facilitate concomitant atrial fibrillation ablation. Different part of the annulus may be visualized to allow more accurate placement of annuloplasty sutures. Through a separate working port, which can be as small as 1.5 to 2 cm, the bedside surgeon can actively assist the console surgeon (Figure 1) . This LEAR approach (lateral endoscopic approach with robotics) as championed by Dr Murphy can reproduce accurately and efficiently the time tested open mitral repair techniques to achieve both durable results and quick patient recovery.1Murphy D.A. Moss E. Binongo J. Miller J.S. Macheers S.K. Sarin E.L. et al.The expanding role of endoscopic robotics in mitral valve surgery: 1,257 consecutive procedures.Ann Thorac Surg. 2015; 100 (discussion 81-2): 1675-1681Abstract Full Text Full Text PDF PubMed Scopus (81) Google Scholar It is our belief that the ability to tailor the repair to different patient circumstances, rather than a “one-size fits all” approach, will result in high rates of the ideal repair. The ideal repair is one in which there is no MR, no mitral stenosis, and a significant coaptation surface below the level of the mitral annulus with low stress forces on the chordae and the leaflets. A typical repair for degenerative posterior leaflet disease in our hands through the robotic approach would be as follows:1.Triangular resection and repair2.Polytetrafluoroethylene neochords to the posterior leaflet3.Cleft repair4.Delamination of the anterior leaflet5.Complete annuloplasty ring The aim of the first step is not to repair the valve but to balance the volume of anterior and posterior leaflet tissue. Step 2 addresses excess leaflet movement, whereas step 3 is necessary when deep clefts are present to provide support to the adjacent scallop. Step 4 is used when there is scarring of the anterior leaflet (Figure 2) . This is common and likely to be related to turbulence and jet lesions. It is like the technique used in rheumatic mitral repair. It increases the length, width, and mobility of the anterior leaflet (Video 1). Using an annuloplasty sizer, we have demonstrated that in most patients the area of the anterior leaflet can be increased by up to one size.Figure 2Steps of robotic mitral valve repair. A, Triangular resection, cleft closure, and polytetrafluoroethylene neochord. B, Anterior leaflet before delamination. C, Anterior leaflet following delamination, demonstrating increase in surface area. D, Saline test post MV repair and annuloplasty, demonstrating near-normal translucency of anterior leaflet.View Large Image Figure ViewerDownload Hi-res image Download (PPT) The same sequence is performed by the authors in the open sternotomy approach. The need for individual components is tailored to the patient's pathology. The robotic platform allowed the exact replica of these techniques without compromise due to limited access. In addition, due to the lack of distortion of the MV from the lateral approach, the saline static test is quite predictive of the final repair morphology and fine tuning of the repair is facilitated. This strategy has evolved over 17 years of experience with robotic MV repair, with the performance of approximately 40 cases a year at the authors' institution. It has enabled a moderate-volume operator to achieve a repair rate for degenerative disease greater than 99%, with low complications and a mortality less than 0.2% (Aubrey Almeida, unpublished data, 2021). However, as many expert mitral surgeons would readily acknowledge, a simple P2 flail in an otherwise-fit and well patient can be performed highly effectively irrespective of approach. However, given the advantages of robotic approach, does it offer any benefit for greater-risk patients with more complex pathology? A number of meta-analyses have shown that minimally invasive MV repair in elderly (>65 years)8Hage A. Hage F. Al-Amodi H. Gupta S. Papatheodorou S.I. Hawkins R. et al.Minimally invasive versus sternotomy for mitral surgery in the elderly: a systematic review and meta-analysis.Innovations (Phila). 2021; 16: 310-316Crossref PubMed Scopus (2) Google Scholar and high risk-patients9Moscarelli M. Fattouch K. Casula R. Speziale G. Lancellotti P. Athanasiou T. What is the role of minimally invasive mitral valve surgery in high-risk patients? A meta-analysis of observational studies.Ann Thorac Surg. 2016; 101: 981-989Abstract Full Text Full Text PDF PubMed Scopus (48) Google Scholar had comparable results with those via the median sternotomy approach. Loulmet and colleagues10Loulmet D.F. Ranganath N.K. Neragi-Miandoab S. Koeckert M.S. Galloway A.C. Grossi E.A. Advanced experience allows robotic mitral valve repair in the presence of extensive mitral annular calcification.J Thorac Cardiovasc Surg. November 2, 2019; ([Epub ahead of print])Abstract Full Text Full Text PDF Scopus (13) Google Scholar presented their data on 64 patients with mitral annular calcification undergoing robotic mitral surgery, which accounted for just less than 13% of their robotic case volume over a 6-year period. The authors reported a 97% MV repair rate with none with more than trace or mild MR at discharge. There was no stroke, and the 30-day mortality was 3.1%. The same authors also analyzed their entire robotic mitral experience over the same period in which 24% (of 500) was considered most complex (bileaflet repair or atrioventricular groove reconstruction for mitral annular calcification) and concluded that despite longer crossclamp time and cardiopulmonary bypass time, the patient outcomes have not worsened despite having more complex repairs.11Loulmet D.F. Ranganath N.K. Neuburger P.J. Nampiaparampil R.G. Galloway A.C. Grossi E.A. Can complex mitral valve repair be performed with robotics? An institution's experience utilizing a dedicated team approach in 500 patients.Eur J Cardiothorac Surg. 2019; 56: 470-478Crossref PubMed Scopus (17) Google Scholar Similarly, Fujita and colleagues12Fujita T. Kakuta T. Kawamoto N. Shimahara Y. Yajima S. Tadokoro N. et al.Benefits of robotically-assisted surgery for complex mitral valve repair.Interact Cardiovasc Thorac Surg. 2021; 32: 417-425Crossref PubMed Scopus (4) Google Scholar presented 9-year data on 335 patients undergoing either robotic or a minithoracotomy approach; 17% and 4% of the repairs, respectively, were considered most complex and the robotic approach was associated with excellent early outcomes. What exactly constitutes a complex repair is also debatable. Repair of bileaflet prolapse is now routine in experienced hands, regardless of the surgical approach. Perhaps a greater challenge is the situation of a deficiency of leaflet tissue and that of abnormal ventricular size and shape. The robotic approach offers improved vision, lack of distortion of the MV, and instruments that function at the tissue plane should provide surgeons with an advantage in these cases. The ability to increase the leaflet area by delamination and make subtle adjustments under accurate vision does enable these valves to be successfully repaired. It is up to the surgeon to use the equipment to optimize patient outcomes. In our opinion, the robotic platform is an adaptive and enabling technology with important advantages over other minimally invasive approaches. However, we would also readily acknowledge that these excellent outcomes are largely based on high-volume centers and that there are definite barriers to achieve the full potential of the robotic approach. The financial aspect of robotic MV surgery is often raised as a concern. Yet, with care, additional costs can be kept to a minimum. As many hospitals already have robotic systems available for other specialties, it is often unnecessary to purchase an additional robotic system. A comparison of 107 robotic mitral repairs to 40 conventional mitral repairs performed at our institution demonstrated a significant reduction in intensive care and hospital stay with a small increase in hospital costs but a reduction in societal cost.13Kam J.K. Cooray S.D. Kam J.K. Smith J.A. Almeida A.A. A cost-analysis study of robotic versus conventional mitral valve repair.Heart Lung Circ. 2010; 19: 413-418Abstract Full Text Full Text PDF PubMed Scopus (41) Google Scholar However, enabling a greater rate of repair is a significant cost advantage when one considers the cost of a prosthetic valve and the cost of lifelong anticoagulation. The robotic console surgeon must not only be facile with the equipment but also have knowledge of how to repair the MV. The robotic approach only facilitates what the surgeon can achieve through open repair. Just as not every surgeon is an expert mitral surgeon, the robotic platform is not for every program. There are technical procedures such as peripheral bypass, techniques of myocardial protection, and setup principles such as patient positioning and port placement that must be mastered. These can be overcome with appropriate training with a learning curve that is real but surmountable. Perhaps the highest hurdle is ensuring that there is dedicated and well-trained team. The roles of anesthesiologist, bedside surgeons, and nursing and technical staff are far more critical than in other operations.14Suri R.M. Dearani J.A. Mihaljevic T. Chitwood Jr., W.R. Murphy D.A. Trento A. et al.Mitral valve repair using robotic technology: safe, effective, and durable.J Thorac Cardiovasc Surg. 2016; 151: 1450-1454Abstract Full Text Full Text PDF PubMed Scopus (51) Google Scholar If one is unable to arrange and keep this dedicated team together, there is little chance of a successful program. In starting a robotic program, patient selection is key and should be adjusted to expertise of the team.15Tang R.C. Murphy D.A. Moss E. Choosing the ideal candidate for a robotic valve intervention.Can J Cardiol. 2021; 37: 1117-1120Abstract Full Text Full Text PDF PubMed Scopus (1) Google Scholar Inherently, a robotic operation will have longer bypass and total operating times, as there are more steps than in a sternotomy approach. Consideration should be given to this in patients with severe left ventricular or right ventricular dysfunction. Other cases to avoid are those with significant aortoiliac disease and those with heavy mitral annular calcification.14Suri R.M. Dearani J.A. Mihaljevic T. Chitwood Jr., W.R. Murphy D.A. Trento A. et al.Mitral valve repair using robotic technology: safe, effective, and durable.J Thorac Cardiovasc Surg. 2016; 151: 1450-1454Abstract Full Text Full Text PDF PubMed Scopus (51) Google Scholar Only when the team has gone through the initial learning curve should it embark on performing procedures on more complex and high-risk patients, in whom the robotic approach probably offers the most benefit. In this sense, robotic mitral surgery may not be the “best” approach for every mitral surgeon, but it may be the most versatile approach for a dedicated mitral surgery team wanting to offer high-quality repair to patients across the entire spectrum of risks. There is no question that patients are looking for less-invasive options to treat heart disease than traditional cardiac surgery. Percutaneous mitral procedures are increasingly offered to treat MR in high-risk and elderly patients, and it is likely this will expand to a wider population. It is critical that surgeons can perform MV surgery in a manner that is most acceptable to patients without any compromise to providing the greatest quality repair. There will always be a disagreement regarding the best approach to minimally invasive MV repair. Good evidence to support one approach over another is currently not available. However, the robotic platform is sophisticated enabling technology, which should help optimize MV repair. It is up to surgeons to ensure the equipment is used in a manner that fulfills this potential.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call