Abstract
Slipped capital femoral epiphyses (SCFE) is associated with out-toeing of the foot and external rotation gait. But it is unknown if SCFE patients treated with the modified Dunn procedure have out-toeing at follow up.Therefore, we used instrumented gait analysis and questioned (1) do severe SCFE patients treated with a modified Dunn procedure have symmetrical foot progression angle (FPA) compared with contralateral side and compared with asymptomatic volunteers (2) what is the prevalence of out-toeing gait and what are the outcome socres at follow up. Gait analysis of 22 patients (22 hips) treated with an unilateral modified Dunn procedure for severe SCFE (slip angle >60 degrees, 2002 to 2011) was retrospectively evaluated. Of 38 patients with minimal 5-year follow up, 2 hips (4%) had avascular necrosis of the femoral head and were excluded for gait analysis. Twenty-two patients were available for gait analysis at follow up (mean follow up of 9±2 y). Mean age at follow up was 22±3 years. Mean preoperative slip angle was 64±8 degrees (33% unstable slips) and decreased postoperatively (slip angle of 8±4 degrees). Gait analysis was performed with computer-based instrumented walkway system (GAITRite) to measure FPA with embedded pressure sensors. Patients were compared with control group of 18 healthy asymptomatic volunteers (36 feet, mean age 29±6 y). (1) Mean FPA of SCFE patients (3.6±6.4 degrees) at follow up was not significantly different compared with their contralateral side (5.6±5.5 degrees) and compared with FPA of controls (4.0±4.5 degrees). (2) Of the 22 SCFE patients, most of them (19 hips, 86%) had normal FPA (-5 to 15 degrees), 2 patients had in-toeing (FPA<-5 degrees) and 1 had out-toeing (FPA >15 degrees) and was not significantly different compared with control group. (3) Mean modified Harris hip score (mHHS) was 93±11 points, mean Hip Disability and Osteoarthritis Outcome Score (HOOS) score was 91±10 points. Three patients (14%) had mHHS <80 points and walked with normal FPA. The 2 patients with in-toeing and one patient with out-toeing had mHHS >95 points. Patients with severe SCFE treated with modified Dunn procedure had mostly symmetrical FPA and good hip scores at long term follow up. This is in contrast to previous studies. Although 1 patient had out-toeing and 2 patients had in-toeing at follow up, they had good hip scores. Level III-retrospective comparative study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.