Abstract

AbstractA newly developed miniature specimen and respective fixture for high temperature low cycle fatigue testing of nickel based single crystal superalloys is presented. Miniaturization allows the preparation of test specimens in all main crystallographic orientations of the cubic nickel crystal using laboratory sized material samples and enables excellent utilization of the costly material. The specimen geometry is optimized by means of parameter studies employing numerical calculations such that for the main crystallographic orientations the stress concentration at the fillet between gauge length and specimen head is minimized, and failure is likely to occur within the gauge length. The designed fixture allows easy specimen mounting and provides sufficient support for applying an extensometer for strain measurement. Protective metallic coatings against oxidation can be applied on the specimen by plasma spraying for studying the effect of coatings on the fatigue lifetime. The functionality of the specimen geometry and fixture design for low cycle fatigue testing is demonstrated for temperatures up to 950 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.