Abstract
We report the results of the development and production of a quantum frequency standard (QFS) based on the coherent population trapping (CPT) resonance observed on the D1 absorption line of 87Rb atoms. The effect of various physical factors on the QFS frequency is studied, and the optimal physical parameters of the device to attain the best frequency stability are determined. The measured relative frequency instability (Allan deviation) is ∼9 × 10−12 for the averaging time of 1 s, 3 ×10−13 for 1000 s, and 1.5 ×10−12 for 24 hours. For a volume of 60 cm3, the power consumption of the entire device is 300 mW. The designed QFS can be used in a new-generation satellite navigation systems with increased accuracy and reliability, as well as for solving a number of other problems of science and technology.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.