Abstract

We describe the design, fabrication, measurement, and performance of a set of cryogenic millimetersubmillimeter wavelength filters used in a balloonborne bolometric radiometer. The set contains single resonant mesh grids used as dichroic beam splitters, resonant meshes in a double quarter-wave configuration, a commercial inductive grid filter, and high-frequency blocking filters. The resultant system has passbands at λ = 1.73, 1.05, 0.61, 0.44 mm with δλ/λ = 0.23, 0.23, 0.12, 0.06. Limits on high-frequency leakage are deduced from laboratory measurements and from the analysis of flight data. The filter set response to three different sources of radiation is presented to show the method and limitations of our characterization. The key element of the filter system is a resonant periodic array of cross-shaped holes etched in thin aluminum. We give an empirical scaling law for the resonant wavelength as a function of structure parameters for aluminum on 25-µm-thick Mylar. Plots of the transmittance for normally incident radiation and the transmittance and reflectance for a 45° incident radiation are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.