Abstract

To extend the service life of the clinched joint, a reconditioning process conducted with an additional tubular rivet was proposed in this work. Different reconditioning forces were employed to produce dissimilar reconditioned joints by experimental method. The experimental results indicated that the neck fracture was the common failure mode of both original clinched and reconditioned joints. Compared with the original clinched joint, the shearing strength of the reconditioned joint produced by a reconditioning force of 40 kN increased from 1810.5 to 1986.47 N, and the energy absorption increased from 2.34 to 3.46 J. The range of effective reconditioning force was from 35 to 40 kN and 40 kN was the best choice for reconditioning the AA5052 failed joints. The mechanical properties of the reconditioned joints are obviously better than those of the original clinched joints, which fully demonstrates that the reconditioning method proposed in this work has a broad prospect of industrial application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.