Abstract

The features of the corrosion process in the artificial defect on the coating obtained by plasma electrolytic oxidation (PEO) method on magnesium MA8 alloy have been investigated using the Localized Electrochemical Impedance Spectroscopy (LEIS), Scanning Vibrating Probe (SVP) techniques along with the Non-Contact Optical Surface Profiler (OSP) technique. The analysis of the experimental data enabled us to suggest that the corrosion process in the defect zone developed predominantly at the magnesium/coating interface. The LEIS technique allows detecting the precision alterations result from corrosion process, which cannot be found by optical image. The data processing has demonstrated a good correlation between the results obtained by a group of methods at all stages of the corrosion process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.