Abstract

For the investigation of inhomogeneous defect distributions the Scanning Positron Microscope (SPM) of the Universität der Bundeswehr München provides a pulsed positron beam with a diameter of about 1 µm and a time resolution of 250 ps (FWHM). To increase the count-rate the SPM is currently transferred to the intense positron source NEPOMUC.To connect the SPM to the NEPOMUC source a special interface was build, which transforms the NEPOMUC beam to the requirements of the SPM. In this contribution we will give an overview of the SPM interface, and its performance. The beam is characterized at the finale stage of the interface, the positron elevator, where the potential energy of the beam is increased, without altering other beam parameters.From our measurements we are able to predict the performance of the SPM at NEPOMUC. In future position resolved measurements will be possible with an improved spatial resolution of about 0.3 µm and an event rate of about 3.7 kHz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.