Abstract

Micro-mapping of terrestrial gamma radiation dose (TGRD) at meter grid spacing in and around four urban homes in Miri City shows rates ranging from 70 to 150 nGy/h. Tiled surfaces (floors and walls) vary between properties and have a clear and significant influence on TGRD which is highest in kitchens, washrooms and toilets. Application of a single indoor value for annual effective dose (AED) may lead to underestimations of up to 30%. The AED is unlikely to exceed 0.8 mSv in homes of this type in Miri, which is within recommended guidelines.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.