Abstract

Thin Layer Activation (TLA) is an ion beam technique. This method consists of an accelerated ion bombardment of the surface of interest of a machine part subjected to wear. Radioactive tracers are created by nuclear reactions in a well defined volume of material. Loss of material owing to wear, corrosion or abrasion phenomena is characterized by monitoring the resulting changes in radioactivity. For the industrial application of this method, special attention has been paid during irradiation to the range of activated thickness, yields and activation homogeneity and to on-line radioactivity measurements. There are two basic methods for measuring the material loss by TLA technique. One of them is based on remanant radioactivity measurements using a previously obtained calibration curve. The second is based on measuring the increasing radioactivity in the lubricant due to suspended wear particles. In this paper, we have chosen to present some calibration curves for both proton and deuteron irradiation of Fe, Cr, Cu, Ti and Ni samples. Thickness ranges are indicated and intrinsic error checking and calculational procedures are also presented. The article ends with a review of some typical experiments involving running-in programme optimization and lubricants certifying procedures.