Abstract

This paper presents an uncertainty budget of measurement on the optical phase on the basis of a metrological analysis inspired from the GUM approach [GUM, Guide to the expression of Uncertainty in Measurement (ISBN 92-67-20188-9, 1993)]. This budget takes account of the procedure implemented in calibrating the phase-shifting device and in the actual phase measurement. This study leads to deriving an estimation of the standard uncertainty in measuring the optical path difference at approximately λ/98. This value agrees with a purely experimental estimate [F. Taillade, Association de la shearographie et des ondes de Lamb pour la detection rapide et quantitative des delaminages, Ph.D. thesis, Technical Note ONERA, NT 2001-3, 2001], which led to a standard uncertainty of roughly λ/108.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.