Abstract
In the frame of the LHC-ATLAS Upgrade of phase I, the New Small Wheel detector system is under integration and commissioning at CERN Laboratories. One of the detector type, the Micromegas detectors, during their integration are tested in several stages for gas tightness validation. In particular, the novel method we are using for the gas tightness test, that we called “Flow Rate Loss”, has been realized in several semi-automatic fixed, portable and stand-alone setups for testing either the Micromegas Quads or the final Double Wedges. The obtained measurements up-to-date are presented as well as their obtained statistical distribution. Additionally, during the performance evaluation of the detectors, a percent oxygen monitoring is also performed in 24-hour base. The methods and techniques we developed and used are presented analytically in this work.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have