Abstract

The paper is concerned with the problem of the development of high-temperature steam turbine power plants with ultra-supercritical (USC) initial parameters. One of the main disadvantages of the USC power unit’s creation is high price due to the application of expensive heat-resistant materials for boiler, live and reheat steam pipelines in turbines. To solve this problem, the following technical improvements to reduce the application of the heat-resistant materials and equipment metal consumption are proposed: horizontal boiler layout, high temperature steam turbine with a cooling system, oxy-hydrogen combustion chambers, and two-tier low-pressure turbine. The influence of the above-mentioned solutions on the high-temperature steam turbine power plant efficiency was estimated using thermodynamic analysis. The promising equipment design was developed based on the results of numerical and experimental research. The analysis of the proposed solutions’ influence upon the economic parameters of a high-temperature power facility was investigated based on the developed cost analysis model, which included the equipment metal and manufacturing expenses. The introduction of all the mentioned cost reduction methods led to a decrease in the facility’s price by RUB 10.5 billion or 15%. The discounted payback period was reduced from 27.5 to 10 years and the net present value increased by RUB 9.6 billion or 16 times.