Abstract
Measurement of Frequency Response Functions (FRFs) on the Millennium Bridge in London was a key part in the validation of the retrofit solution for excessive sway vibration caused by walking pedestrians during the bridge opening in June 2000. The measured FRFs were employed to verify the analytical response analysis and to estimate and confirm analytical predictions of natural frequencies, modal damping ratios, mode shapes and modal masses corresponding to various configurations of prototype viscous and tuned mass dampers. These results were used to experimentally assess the effectiveness of the proposed retrofit solution. Although FRF measurement technology is fairly standard in many engineering disciplines, its application on the Millennium Bridge was quite problematic and required some unique solutions which are described in this paper. Modal testing of the Millennium Bridge clearly demonstrated that it was possible to measure good quality FRFs around a frequency as low as 0·5 Hz, which was the natural frequency of the first lateral mode of vibration. This was achieved by designing, constructing and installing a bespoke hydraulic shaker featuring a translatory moving mass of 1000 kg. As the shaker was not able to produce perfectly sinusoidal excitation for stepped-sine testing, FRFs were successfully estimated using the so-called Resolver method in conjunction with an Hc estimator. The standard H1 FRF estimator, which is used in the vast majority of modern digital spectrum analysers nowadays, was demonstrably unable to produce meaningful FRF estimates when using the Resolver approach. The FRF estimation and curve-fitting performed in situ proved to be crucial for the success of the modal testing of the Millennium Bridge. By evaluating the estimates of the experimental FRFs and the corresponding modal properties during the testing programme on site, a number of test errors were spotted. This, in turn, enabled immediate repetition of measurements and/or evaluation of the structural behaviour which would have been impossible if the FRF data analysis had been performed after the testing had been completed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Civil Engineers - Structures and Buildings
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.