Abstract

Shaker excitation in FRF (Frequency Response Function) measurement of a testing system can be controlled by using swept-sine signal source in a signal generator and it is called with swept-sine excitation. FRF’s magnitude error of the system which is obtained from the FRF measurement using swept-sine excitation depends on swept function of swept-sine signal. In this paper, swept-sinesignals using linear and S535 swept functions have been simulated to controlling swept-sine excitation in the FRF measurement of SDOF (Single Degree of Freedom) system. Linear swept is swept function of swept-sine signal which is often used in the FRF measurement and S535swept is a swept function has been developed in this paper. Based on simulation results, the FRF’s magnitude error at system’s resonant frequency which was obtained from the FRF measurement using linear swept-sine excitation can be minimized by redoing the FRF measurement using S535 swept-sine excitation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.