Abstract

In this paper, we present novel methods for automated pulse shape discrimination. The classifiers are trained using simple radionuclide sources and do not require ground truth labeling. We test their performance using labels derived from time of flight experiments and present the results in terms of energy-dependent Receiver Operating Characteristic (ROC) curves. In addition, we also train and test standard pulse shape discrimination methods on the same data for comparison. We find multiple methods that can yield similar false neutron and true neutron rates at 24keVee as tail-to-total or Gatti’s optimal linear filter yield at 54keVee.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.