Abstract

The cables of high-strength carbon fiber reinforced polymer (CFRP) plates are starting to be applied to large spatial structures. However, their main anchorage systems rely on the adhesive force, which entails risks to their integrity resulting from aging of the binding agent. In this study, a friction-based wedge anchorage system was designed for CFRP plates. The working mechanism of the proposed anchorage system was explored both theoretically and experimentally. The anti-slip mechanism and condition of CFRP plates were formulated so that the equivalent frictional angle of the contact surface between a CFRP plate and wedges must not be smaller than the sum of the dip angle of the wedge external conical surface and the frictional angle between the wedges and barrel. An analysis of the stress distribution in the anchorage zone of the CFRP plate was conducted using the Tsai-Wu failure criterion, which concluded that the compressive stresses should be reduced on the section closer to the load-bearing end of the anchorage system. Furthermore, the anchorage efficiency coefficient was proposed, which depends on stress concentration coefficients, plate thickness, length of anchorage zone, dip angle of wedge external conical surface, and its frictional angle. Then, it was determined that the minimum length of an anchorage zone for the CFRP plates with various specifications should be at least 49 times larger than the CFRP thickness. A finite element analysis and static tensile tests on six specimens were carried out. The experimental results revealed that the anchorage efficiency coefficient of the optimized anchor reached 97.9%.

Highlights

  • The cables of high-strength carbon fiber reinforced polymer (CFRP) plates are starting to be applied to large spatial structures

  • It can be demonstrated that: where F is the tensile force in CFRP plate, and f1 and N1 are the frictional and normal force acting on Interface 1, respectively

  • Coefficients Fi and Fij, which are related to the strength of CFRP plate material, can be obtained from experimental data according to the following formulas:

Read more

Summary

Theoretical Analysis

The failure of a wedge-type anchor for CFRP plates can generally be of three types [31]: slip failure, pinch-off failure, and CFRP plate tensile failure. The wedge-type anchor can experience slip failure or CFRP plate pinch-off failure due to excessive relative displacement or compressive stress in the CFRP plates in the anchorage zone. The CFRP plates are susceptible to tensile failure when both longitudinal displacement and compressive stress are uniformly distributed within a certain zone, providing an ideal anchoring effect. Materials 2021, 14, x FOR PEER REVIEW compressive stress in CFRP plates in the anchorage zone, so that the CFRP plates can be clamped tightly without excessive damage.

Anti-Slip Mechanism
Stress
Factors Influencing Anchorage Efficiency Coefficient
Determination of Parameters
Finite element analysis
50 Figure mm
10. Schematic
11. Typical
12. Anchorage
Conclusions