Abstract

Phytic acid (PA) plays different roles in various fields of study, yet current analytical methods for PA detection are still unsatisfactory. A novel method has been presented for the determination of PA in beverages, based on complete methylation in combination with liquid chromatography-mass spectrometry (LC-MS) analysis. By treatment with (trimethylsilyl) diazomethane, all the polybasic acid groups in PA were converted to the corresponding ester, and thus the corresponding derivative was easily analyzed by LC-MS. The addition of ethylenediamine tetraacetic acid (EDTA) to the derivative solution improved the sensitivity and the reproducibility in the PA analysis. Under optimized parameters, the linear range of the PA detection was 0.5–100 μg/L, the limit of detection was 0.075 μg/L, the limit of quantitation was 0.25 μg/L, and the recovery range was 81.3–119.7 %. The PA content was determined for 13 commercially available beverage samples, and experimental results showed that this method provided a practical and reliable method for the detection of PA across diverse beverage matrices.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.