Abstract

In the process of developing a thermocompensated quartz generator, it was necessary to calculate the reliability indicators of such an important element of the circuit as a quartz resonator for a failure-free period of 15 000 hours. The main parameter that can be used to evaluate the reliability of the quartz resonator is the stability of the nominal oscillation frequency. It is the stability of the nominal frequency of the resonator that formed the basis of the new developed technique. The method includes rules for constructing a probabilistic and statistical model of the dependence of the resonator frequency change on the test time. The article describes the work done on the accelerated evaluation of the reliability of piezoelectric resonators RK563 on the basis of probabilistic and statistical modeling of the behavior of the frequency from the test time. The method of mathematical modeling is based on the results of incomplete tests for a period of 30…50 % of the set value of the minimum operating time.